The DC brake module only, din rail / chassis mounting device IP20 to be mounted in an existing or new control system. Additional contactors & fuses may be required. Must be interlocked to prevent starting whilst braking & to de-energize running when braking. Please download this datasheet.
Specification below:
These are our standard DC injection brake modules. They can be set for 0-10 seconds of braking. There's a one second delay and 0.2 seconds ramp time before the braking current is applied to the motor, this makes these modules suitable for frequent braking every time the motor stops.
Model Number | Motor connected for DOL |
Motor connected for Star/Delta |
Motor Voltage | Max. Brake Current |
||
kW | HP | kW | HP | |||
400V | ||||||
INJ-H-25A-IH | 5.5kW | 7.5HP | 11kW | 15HP | 380-415V | 25A |
INJ-H-50A-IH | 11kW | 15HP | 22kW | 30HP | 380-415V | 50A |
INJ-H-75A-ASS-IH | 18.5kW | 25HP | 37kW | 50HP | 380-415V | 75A |
INJ-H-120A-ASS-IH | 30kW | 40HP | 55kW | 75HP | 380-415V | 120A |
INJ-H-220A-ASS-IH | 55kW | 75HP | 110kW | 150HP | 380-415V | 220A |
220-230V | Single Phase Operation |
3 Phase 220- 230V Operation |
||||
INJ-L-25A-IH | 2.2kW | 3HP | 3.0kW | 4HP | 220-240V | 25A |
INJ-L-50A-IH | 4.0kW | 5.5HP | 7.5kW | 10HP | 220-240V | 50A |
The table below shows our DC injection brake modules which have extended braking time, designed for motors high inertia that can't be stopped within 10 seconds. They can be set for 0-30 seconds of braking, but due to the amount of extra duty and the resulting heat they have lower power rating. There's also a one second delay and 0.2 seconds ramp time before the braking current is applied to the motor, this makes these modules suitable for frequent braking every time the motor stops.
Model Number | Motor connected for DOL |
Motor connected for Star/Delta |
Motor Voltage | Max. Brake Current |
||
kW | HP | kW | HP | |||
400V | ||||||
INJ-H-25A-30S | 4.0kW | 5.5HP | 7.5kW | 10HP | 380-415V | 25A |
INJ-H-50A-30S | 7.5kW | 10HP | 18.5kW | 25HP | 380-415V | 50A |
INJ-H-75A-ASS-30S | 15kW | 20HP | 30kW | 40HP | 380-415V | 75A |
INJ-H-120A-ASS-30S | 22kW | 30HP | 45kW | 60HP | 380-415V | 120A |
INJ-H-220A-ASS-30S | 45kW | 60HP | 90kW | 120HP | 380-415V | 220A |
220-230V | Single Phase Operation |
3 Phase 220- 230V Operation |
||||
INJ-L-25A-30S | 1.5kW | 2HP | 2.2kW | 3HP | 220-240V | 25A |
INJ-L-50A-30S | 3.0kW | 4HP | 5.5kW | 7.5HP | 220-240V | 50A |
Below are our fast acting DC injection brake modules, intended for emergency operation. They can be set for 0-10 seconds of braking. There's no delay and the braking current is applied to the motor in full with no ramp time, this makes these modules suitable for infrequent braking, such as emergency stops. For applications were, under normal stopping, the motor would coast.
Model Number | Motor connected for DOL |
Motor connected for Star/Delta |
Motor Voltage | Max. Brake Current |
||
kW | HP | kW | HP | |||
400V | ||||||
INJ-H-25A-EMR | 5.5kW | 7.5HP | 11kW | 15HP | 380-415V | 25A |
INJ-H-50A-EMR | 11kW | 15HP | 22kW | 30HP | 380-415V | 50A |
INJ-H-75A-ASS-EMR | 18.5kW | 25HP | 37kW | 50HP | 380-415V | 75A |
INJ-H-120A-ASS-EMR | 30kW | 40HP | 55kW | 75HP | 380-415V | 120A |
INJ-H-220A-ASS-EMR | 55kW | 75HP | 110kW | 150HP | 380-415V | 220A |
220-230V | Single Phase Operation |
3 Phase 220- 230V Operation |
||||
INJ-L-25A-EMR | 2.2kW | 3HP | 3.0kW | 4HP | 220-240V | 25A |
INJ-L-50A-EMR | 4.0kW | 5.5HP | 7.5kW | 10HP | 220-240V | 50A |